H9 ASD Installation and Operation Manual

229

Analog Function Assigned Object 21

Program

My Function

My Function Analog

This parameter plays a role in the setup of the My Function feature by
selecting the functionality to which the adjustment of

F962

is applied.

Settings:

0 — Disabled (None)
1 — Acceleration Rate
2 — Upper Limit Frequency
3 — Acceleration Multiplication Factor
4 — Deceleration Multiplication Factor
5 — Manual Torque Boost
6 — Over Current Stall (

F601

)

7 — Thermal Protection
8 — Speed Loop P Gain (

F460

)

9 — Drooping Gain (

F320

)

10 — PID P Gain (

F362

)

See the My Function Instruction Manual (P/N 58692) for a complete
description of the setup requirements and operational information of the Analog
Function Assigned Object
parameter.

Direct Access Number — F964

Parameter Type — Selection List

Factory Default — 0 (Disabled)

Changeable During Run — Yes

Monitor Output Function 11

Program

My Function

My Function Monitor

This parameter plays a role in the setup of the My Function feature by
establishing the function that is to be recorded and output as the Peak,
Minimum, or Average value as selected at parameter

F966

.

Select the Monitor Display Input Setting number from

Table 10 on pg. 243

to

output the corresponding function.

Use the Communication Number if operating using communications.

See the My Function Instruction Manual (P/N 58692) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.

Direct Access Number — F965

Parameter Type — Selection List

Factory Default — 2000

Changeable During Run — Yes

Monitor Output Function Command 11

Program

My Function

My Function Monitor

This parameter plays a role in the setup of the My Function feature by allowing
the user to select the Peak, Minimum, or Normal (Avg.) value of the
parameter

F965

selection to be recorded and output as a monitored function.

Settings:

0 — Normal
1 — Peak
2 — Minimum

See the My Function Instruction Manual (P/N 58692) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.

Direct Access Number — F966

Parameter Type — Selection List

Factory Default — Normal

Changeable During Run — Yes

F964