Reset, F114, F115 – Toshiba H9 User Manual

Page 97: F116, F117, F118

Advertising
background image

H9 ASD Installation and Operation Manual

89

Input Terminal 4 (RES) Function

Program

Terminal

Input Terminals

This parameter is used to set the functionality of the RES discrete input
terminal.

In addition, this input terminal must be specified as Normally Open or
Normally Closed.

This parameter sets the programmable RES terminal to any one of the user-
selectable functions listed in

Table 5 on pg. 236

.

Direct Access Number — F114

Parameter Type — Selection List

Factory Default — Reset

Reset

Changeable During Run — No

Input Terminal 5 (S1) Function

Program

Terminal

Input Terminals

This parameter is used to set the functionality of the S1 discrete input terminal.

In addition, this input terminal must be specified as Normally Open or
Normally Closed.

This parameter sets the programmable S1 terminal to any one of the user-
selectable functions listed in

Table 5 on pg. 236

.

Direct Access Number — F115

Parameter Type — Selection List

Factory Default — Preset Speed 1

Changeable During Run — No

Input Terminal 6 (S2) Function

Program

Terminal

Input Terminals

This parameter is used to set the functionality of the S2 discrete input terminal.

In addition, this input terminal must be specified as Normally Open or
Normally Closed.

This parameter sets the programmable S2 terminal to any one of the user-
selectable functions listed in

Table 5 on pg. 236

.

Direct Access Number — F116

Parameter Type — Selection List

Factory Default — Preset Speed 2

Changeable During Run — No

Input Terminal 7 (S3) Function

Program

Terminal

Input Terminals

This parameter is used to set the functionality of the S3 discrete input terminal.

In addition, this input terminal must be specified as Normally Open or
Normally Closed.

This parameter sets the programmable S3 terminal to any one of the user-
selectable functions listed in

Table 5 on pg. 236

.

Direct Access Number — F117

Parameter Type — Selection List

Factory Default — Preset Speed 3

Changeable During Run — No

Input Terminal 8 (S4) Function

Program

Terminal

Input Terminals

This parameter is used to set the functionality of the S4 discrete input terminal.

In addition, this input terminal must be specified as Normally Open or
Normally Closed.

This parameter sets the programmable S4 terminal to any one of the user-
selectable functions listed in

Table 5 on pg. 236

.

Direct Access Number — F118

Parameter Type — Selection List

Factory Default — Preset Speed 4

Changeable During Run — No

F114

F118

Advertising