H9 ASD Installation and Operation Manual

141

Automatic Light-Load High-Speed Operation Frequency

Program

Special

Crane/Hoist Settings

This parameter establishes the speed to which the ASD will ramp when
operating in the Light-Load High-Speed mode.

Direct Access Number — F330

Parameter Type — Numerical

Factory Default — 60.00

Changeable During Run — No

Minimum — 30.00

Maximum — Upper Limit (

F012

)

Units — Hz

Light-Load High-Speed Operation Switching Lower-Limit

Frequency

Program

Special

Crane/Hoist Settings

This parameter sets an output frequency threshold that, once surpassed, allows
the Light-Load High-Speed function to be used.

The Light-Load High-Speed function may be used if the frequency threshold
set at this parameter and the following conditions are met:

1) Light-Load High-Speed Operation Enable is configured at

F328

.

2) The output torque is less than the setting established in

F335

when reaching

the frequency setting here.

Direct Access Number — F331

Parameter Type — Numerical

Factory Default — 40.00

Changeable During Run — Yes

Minimum — 30.0

Maximum — Upper Limit (

F012

)

Units — Hz

Light-Load High-Speed Operation Load Wait Time

Program

Special

Crane/Hoist Settings

After the time setting of

F333

times out, this parameter determines the length of

time that the Light-Load High-Speed criteria must be met until the Light-
Load High-Speed
function engages.

Direct Access Number — F332

Parameter Type — Numerical

Factory Default — 0.5

Changeable During Run — Yes

Minimum — 0.0

Maximum — 10.0

Units — Seconds

Light-Load High-Speed Operation Detection Time

Program

Special

Crane/Hoist Settings

This parameter determines the length of time that the load requirement must
meet the Light-Load High-Speed criteria before the Light-Load High-Speed
Enable
(

F328

) is recognized.

Once recognized, the timer setting of

F332

must expire to engage the Light-

Load High-Speed function.

Direct Access Number — F333

Parameter Type — Numerical

Factory Default — 1.0

Changeable During Run — Yes

Minimum — 0.0

Maximum — 10.0

Units — Seconds

Light-Load High-Speed Operation Heavy-Load Detection

Time

Program

Special

Crane/Hoist Settings

While operating in the Light-Load High-Speed mode, this parameter
determines the length of time that a load exceeding the Light-Load High-
Speed
operation criteria may exist before the Light-Load High-Speed mode is
terminated and normal operation resumes.

Direct Access Number — F334

Parameter Type — Numerical

Factory Default — 0.5

Changeable During Run — Yes

Minimum — 0.0

Maximum — 10.0

Units — Seconds

F330

F334