Eoi command mode on pg. 42, Eoi command mode – Toshiba H9 User Manual

Page 50

Advertising
background image

42

H9 ASD Installation and Operation Manual

EOI Command Mode

The EOI Command mode is accessed by pressing the ESC key from the Frequency Command screen.

The control settings of the EOI Command menu are effective for EOI control only.

The EOI Command mode provides quick access to the following menu parameters:

Direction

Forward or Reverse.

Stop Pattern

— The Decel Stop or Coast Stop settings determines the method used to stop the

motor when using the Stop|Reset key of the EOI. The Decel Stop setting enables the Dynamic
Braking
system setup at

F304

or the DC Injection Braking system setup at

F250

,

F251

, and

F252

.

The Coast Stop setting allows the motor to stop at the rate allowed by the inertia of the load.

Note:

The Stop Pattern setting has no effect on the Emergency Off settings of

F603

.

V/f Group

— 1 of 4 V/f profiles may be selected and run. Each V/f profile is comprised of 4 user

settings: Base Frequency, Base Frequency Voltage, Manual Torque Boost, and Electronic
Thermal Protection
. Expanded descriptions of these parameters may be found in the section titled

Direct Access Parameter Information on pg. 76

.

Accel/Decel Group

— 1 of 4 Accel/Decel profiles may be selected and run. Each of the Accel/

Decel profiles is comprised of 3 user settings: Acceleration, Deceleration, and Pattern. Expanded
descriptions of these parameters may be found in the section titled

Direct Access Parameter

Information on pg. 76

(or see

F009

).

Feedback in Panel Mode

— This feature enables or disables the PID feedback function.

Torque Limit Group

— This parameter is used to select 1 of 4 preset positive torque limits to apply

to the active motor (of a multiple motor configuration). The settings of profiles 1 – 4 may be setup at

F441

,

F444

,

F446

, and

F448

, respectively.