Monitor mode, Pg. 43 – Toshiba H9 User Manual

Page 51

Advertising
background image

H9 ASD Installation and Operation Manual

43

Monitor Mode

The Monitor mode allows the user to monitor motor performance variables, control settings, and
configuration data during motor operation. There are 43 items that may be monitored from this mode. The
items are listed and described below.

Note:

The Monitor mode is a read-only mode. The settings cannot be changed from the
Monitor mode. For information on how to change the values, see the section titled

Default Setting Changes on pg. 74

.

Note:

Any two of the Underlined monitored items may be selected for display at the
Frequency Command screen while running via Program

Utilities

Main

Monitor Selections

.

Note:

The

F701

setting will determine if the Current and Voltage values displayed appear

as A (Amps) or V (Voltage), or if the value is shown as a

%

(percentage) of the ASD

rating.

Frequency at Trip

Display the at-trip frequency.

Frequency Reference

— Displays the Frequency Setpoint (also called the Commanded

Frequency).

Output Current

— Displays the Output Current as a percentage of the rated capacity of the H9

ASD.

DC Bus Voltage

— Displays the Bus Voltage as a percentage of the rated capacity of the H9 ASD.

Output Voltage

— Displays the Output Voltage as a percentage of the rated capacity of the H9

ASD.

AM Output

— Displays the AM output terminal value for the function assigned to the AM terminal.

FM Output

Displays the FM output terminal value for the function assigned to the FM terminal.

Motor OL (Overload) Real

Displays the real-time Motor Overload value as a percentage of

the rated capacity of the motor.

Motor OL (Overload) Trip

Displays the Motor Overload Trip value as a percentage of the

rated capacity of the motor.

Motor Load

— Displays the real-time Motor Load as a percentage of the rated capacity of the

motor.

ASD OL (Overload) Real

— Displays the real-time ASD Overload as a percentage of the rated

capacity of the H9 ASD.

ASD OL (Overload) Trip

Displays the ASD Overload Trip value as a percentage of the rated

capacity of the ASD.

ASD Load

— Displays the ASD Load as a percentage of the rated capacity of the H9 ASD.

Run Time

— Displays the Cumulative Run Time in hours.

Compensation Frequency

— Displays the Output Frequency after the application of the slip

compensation correction value (Post Compensation Frequency).

DBR OL (Overload) Real

— Displays the real-time DBR Overload value as a percentage of the

Dynamic Braking Resistor capacity.

DBR OL (Overload) Trip

— Displays the DBR Overload Trip value as a percentage of the

Dynamic Braking Resistor capacity.

DBR Load

— Displays the DBR Load as a percentage of the Dynamic Braking Resistor capacity.

Feedback (inst)

— Provides a status of the Real Time Feedback in Hz.

Feedback (1 second)

— Provides a status of the 1-Second Averaging feedback in Hz.

Advertising