F342, F343, F344 – Toshiba H9 User Manual

Page 151: F345, F346

Advertising
background image

H9 ASD Installation and Operation Manual

143

Torque Bias Input Selection

Program

Torque

Torque Control

Once enabled at parameter

F341

, this parameter sets the source of the input

signal that will set the torque level used for to provide the Braking Mode
Selection
function of parameter

F341

.

Settings:

0 — Disabled
1 — V/I
2 — RR
3 — RX
4 — Panel Keypad
5 — RS485 2-Wire
6 — RS485 4-Wire
7 — Communication Option Board
8 — RX2 Option (AI1)

Direct Access Number — F342

Parameter Type — Selection List

Factory Default — Disabled

Changeable During Run — Yes

Panel Torque Bias

Program

Torque

Torque Control

Once enabled at parameter

F341

, this parameter establishes the torque bias

setting to which the setting of

F342

will either add to or subtract from to

produce the final torque value used to carry out the Braking Mode Selection
function of parameter

F341

.

Direct Access Number — F343

Parameter Type — Numerical

Factory Default — 100.00

Changeable During Run — Yes

Minimum — -250.00

Maximum — +250.00

Units — %

Panel Torque Gain

Program

Torque

Torque Control

Once enabled at parameter

F341

, this parameter sets the sensitivity of the

torque control source selected at

F342

for the Braking Mode Selection

function of parameter

F341

.

Direct Access Number — F344

Parameter Type — Numerical

Factory Default — 100.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 100.00

Units — %

Release Time

Program

Torque

Torque Control

Once enabled at parameter

F341

, this parameter sets the time that the brake will

hold after the requirements of the Braking Mode Selection function of
parameter

F341

have been met.

Direct Access Number — F345

Parameter Type — Numerical

Factory Default — 0.05

Changeable During Run — Yes

Minimum — 0.00

Maximum — 2.50

Units — Seconds

Creeping Frequency

Program

Torque

Torque Control

Once enabled at parameter

F341

, and while running, upon receiving a Stop

command this parameter sets an output frequency to be provided for the
duration of the time setting of parameter

F347

.

Direct Access Number — F346

Parameter Type — Numerical

Factory Default — 3.00

Changeable During Run — Yes

Minimum —

F240

Setting

Maximum — 20.0

Units — Hz

F342

F346