F740, F741, F742 – Toshiba H9 User Manual

Page 211

Advertising
background image

H9 ASD Installation and Operation Manual

203

Trace Selection

Program

Utilities

Trace

In conjunction with parameter

F741

F745

, this parameter is used to monitor

and store 4 ASD output waveform data points. The data may be read and stored
as a function of a trip (At Trip) or it may be initiated by the activation of a
discrete terminal activation (At Trigger). Set a discrete input terminal to Trace
Back Trigger Signal
and activate the terminal to initiate the At Trigger read/
store function.

Table 9 on pg. 242

lists the items that may be selected for the data read/store

function along with the associated communication number for each selection.

The duration of the read/store cycle for the selected items is set at parameter

F741

.

To acquire and store the data a communications device and a PC are required.
The H9 ASD supports the following communications protocols: RS485
(MODBUS-RTU) Toshiba Protocol, USB Toshiba Protocol, CC-Link, ProfiBus,
and DeviceNet (Refer to the manual of each protocol type for more
information).

Trace data may be viewed graphically via Program

⇒ Utilities ⇒ View Trace

Data.

Settings:

0 — None (disabled)
1 — At Trip
2 — At Trigger

Direct Access Number — F740

Parameter Type — Selection List

Factory Default — At Trip

Changeable During Run — Yes

Trace Cycle

Program

Utilities

Trace

This parameter sets the record time for the Trace Data events selected at

F742

F745

.

See

F740

for more information on this parameter setting.

Settings:

0 — 4 mS
1 — 20 mS
2 — 100 mS
3 — 1 Second
4 — 10 Seconds

Direct Access Number — F741

Parameter Type — Selection List

Factory Default — 100 mS

Changeable During Run — Yes

Trace Data 1

Program

Utilities

Trace

This parameter is used to select the Trace Data 1 item from

Table 9 on pg. 242

to be read and stored in accordance with the setup of parameters

F740

and

F741

.

See

F740

for more information on this parameter setting.

Direct Access Number — F742

Parameter Type — Selection List

Factory Default — Output Frequency

Changeable During Run — Yes

F740

F742