H9 ASD Installation and Operation Manual

Drooping Insensitive Torque

Program

Feedback

Drooping Control

This parameter defines a torque range in which the Drooping Control settings
will be ignored and the programmed torque settings will be followed.

Direct Access Number — F323

Parameter Type — Numerical

Factory Default — 10.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 100.0

Units — %

Drooping Output Filter

Program

Feedback

Drooping Control

This parameter is used to set the rate of output change allowed when operating
in the Drooping Control mode.

Jerky operation may be reduced by increasing this setting.

Direct Access Number — F324

Parameter Type — Numerical

Factory Default — 100.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 200.0

Units — Radians/Second

Light-Load High-Speed Operation

Program

Special

Crane/Hoist Settings

This parameter enables the Light-Load High-Speed function by selecting an
operating mode. The Light-Load High-Speed function accelerates the output
frequency of the ASD from the programmed speed to the setting established in

F330

.

This parameter may be disabled.

Enabling the Light-Load High-Speed function requires that an operating mode
be selected here, and that the criteria of parameters

F331

F333

be met.

Settings:

0 — Off
1 — Auto Speed (F-Motor: Up, R-Generator:Down)
2 — Auto Speed (F-Generator: Down, R-Motor:Up)
3 —

F330

Setting (F-Motor: Up, R-Generator:Down)

4 —

F330

Setting (F-Generator: Down, R-Motor:Up)

Direct Access Number — F328

Parameter Type — Selection List

Factory Default — Off

Changeable During Run — Yes

Light-Load High-Speed Learning Function

Program

Special

Crane/Hoist Settings

The Light-Load High-Speed function accelerates the output frequency of the
ASD from the programmed speed to the setting established in

F330

and is

primarily used with Crane/Hoist functions.

During Light-Load High-Speed operation with this parameter enabled,
parameters Panel Torque Bias (

F343

), Creep Frequency (

F346

), and the

Creep Time (

F347

) are set to a standard set of light-load profile values.

Application-specific adjustments may be required.

Note:

This function should be setup with a light load only.

Settings:

0 — Off
1 — Forward/Reverse
2 — Forward Only

Direct Access Number — F329

Parameter Type — Selection List

Factory Default — Off

Changeable During Run — No

F323