F335, F336, F337 – Toshiba H9 User Manual

Page 150: F338, F341

Advertising
background image

142

H9 ASD Installation and Operation Manual

Switching Load Torque During Power Running

Program

Special

Crane/Hoist Settings

During power running, this parameter establishes the threshold torque level that
is used to determine if the Light-Load High-Speed (

F328

) operation may

engage or remain engaged if active.

If the Light-Load High-Speed operation is terminated normal operation
resumes.

Note:

Power running may be during forward, reverse, acceleration, or
deceleration, but not during regeneration.

Direct Access Number — F335

Parameter Type — Numerical

Factory Default — 50.00

Changeable During Run — No

Minimum — -250.00

Maximum — +250.00

Units — %

Heavy-Load Torque During Power Running

Program

Special

Crane/Hoist Settings

During power running, this parameter establishes the threshold torque level that
is used to determine if the Light-Load High-Speed (

F328

) operation may

engage or remain engaged if active.

If the Light-Load High-Speed operation is terminated normal operation
resumes.

Direct Access Number — F336

Parameter Type — Numerical

Factory Default — 100.00

Changeable During Run — Yes

Minimum — -250.00

Maximum — +250.00

Units — %

Heavy-Load Torque During Constant Power Running

Program

Special

Crane/Hoist Settings

During constant power running, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (

F328

) operation

may engage or remain engaged if active.

If the Light-Load High-Speed operation is terminated normal operation
resumes.

Direct Access Number — F337

Parameter Type — Numerical

Factory Default — 50.00

Changeable During Run — Yes

Minimum — -250.00

Maximum — +250.00

Units — %

Switching Load Torque During Regenerative Braking

Program

Special

Crane/Hoist Settings

During regenerative braking, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (

F328

) operation

may engage or remain engaged if active.

If the Light-Load High-Speed operation is terminated normal operation
resumes.

Direct Access Number — F338

Parameter Type — Numerical

Factory Default — 50.00

Changeable During Run — Yes

Minimum — -250.00

Maximum — +250.00

Units — %

Braking Mode Selection

Program

Torque

Torque Control

This parameter is primarily used with lifting systems to allow for enough torque
to be produced after receiving a Run command before releasing the brake.
Without this feature the load would drop for a period once the brake was
released.

This parameter enables this function by setting the system operating mode.

Settings:

0 — Disabled
1 — Forward Direction
2 — Reverse Direction
3 — Same Direction

Direct Access Number — F341

Parameter Type — Selection List

Factory Default — Disabled

Changeable During Run — Yes

F335