User notification codes, Alarms, User notification codes alarms – Toshiba H9 User Manual

Page 255

Advertising
background image

H9 ASD Installation and Operation Manual

247

User Notification Codes

The User Notification codes appear in the top right corner of the Frequency Command screen while the
associated function is active.

User Notification codes notify the user of active functions that are usually only momentary under normal
conditions and are active for the duration of activation only. User notification events are not error
conditions and only convey active system functions to the user.

Table 12. User Notification codes.

Alarms

Table 13

lists the alarm codes that may be displayed during operation of the H9 ASD. Each alarm code

listed is accompanied by a description and a possible cause. In the event that the source of the malfunction
cannot be determined, contact your Toshiba Sales Representative for further information on the condition
and for an appropriate course of action.

The Alarms are listed in the top-down order that they are checked for activation. Only the first to be
detected will be displayed on the Frequency Command screen.

Table 13. H9 ASD Alarms.

LED

Function

Description

Atn

Autotune active

Atn indicates that the Autotune function is active.

dbOn

DC Braking

This code conveys the DC Injection function being carried out. The display shows db when
braking and shows dbOn when the motor shaft stationary function is being carried out.

LED

Display

LCD

Display

Description

Possible Causes

CM1

Comm1 Error

Internal communications error.

• Improperly programmed ASD.

• Improper communications settings.

• Improperly connected cables.

CM2

Comm2 Error

External communications error.

E

Emergency Off

Output signal from the ASD is
terminated and a brake may be
applied if so configured.

• Stop|Reset pressed twice at the EOI.

• EOFF command received remotely.

• ASD reset required.

MOFF

Main
Undervoltage

Undervoltage condition at the

3-phase AC input to the ASD.

• Low 3-phase commercial voltage.

Advertising