F540, F541, F542 – Toshiba H9 User Manual

Page 185: F543, F544, F545

Advertising
background image

H9 ASD Installation and Operation Manual

177

Speed 1 Operation Time

Program

Pattern Run

Operation Time

This parameter sets the run-time for Preset Speed #1.

This time is effective when used with Group Speeds and non-Group Speeds.

If the Auto-Restart function is activated, the search time required for the Auto-
Restart
function will be subtracted from the Operation Time setting; resulting
in a shorter run time.

Direct Access Number — F540

Parameter Type — Numerical

Factory Default — 5.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 6000.0

Units —

F520

Setting

Speed 2 Operation Time

Program

Pattern Run

Operation Time

This parameter sets the run-time for Preset Speed #2.

This time is effective when used with Group Speeds and non-Group Speeds.

If the Auto-Restart function is activated, the search time required for the Auto-
Restart
function will be subtracted from the Operation Time setting; resulting
in a shorter run time.

Direct Access Number — F541

Parameter Type — Numerical

Factory Default — 5.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 6000.0

Units —

F520

Setting

Speed 3 Operation Time

Program

Pattern Run

Operation Time

This parameter sets the run-time for Preset Speed #3.

This time is effective when used with Group Speeds and non-Group Speeds.

If the Auto-Restart function is activated, the search time required for the Auto-
Restart
function will be subtracted from the Operation Time setting; resulting
in a shorter run time.

Direct Access Number — F542

Parameter Type — Numerical

Factory Default — 5.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 6000.0

Units —

F520

Setting

Speed 4 Operation Time

Program

Pattern Run

Operation Time

This parameter sets the run-time for Preset Speed #4.

This time is effective when used with Group Speeds and non-Group Speeds.

If the Auto-Restart function is activated, the search time required for the Auto-
Restart
function will be subtracted from the Operation Time setting; resulting
in a shorter run time.

Direct Access Number — F543

Parameter Type — Numerical

Factory Default — 5.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 6000.0

Units —

F520

Setting

Speed 5 Operation Time

Program

Pattern Run

Operation Time

This parameter sets the run-time for Preset Speed #5.

This time is effective when used with Group Speeds and non-Group Speeds.

If the Auto-Restart function is activated, the search time required for the Auto-
Restart
function will be subtracted from the Operation Time setting; resulting
in a shorter run time.

Direct Access Number — F544

Parameter Type — Numerical

Factory Default — 5.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 6000.0

Units —

F520

Setting

Speed 6 Operation Time

Program

Pattern Run

Operation Time

This parameter sets the run-time for Preset Speed #6.

This time is effective when used with Group Speeds and non-Group Speeds.

If the Auto-Restart function is activated, the search time required for the Auto-
Restart
function will be subtracted from the Operation Time setting; resulting
in a shorter run time.

Direct Access Number — F545

Parameter Type — Numerical

Factory Default — 5.0

Changeable During Run — Yes

Minimum — 0.1

Maximum — 6000.0

Units —

F520

Setting

F540

F545