H9 ASD Installation and Operation Manual

165

Acc/Dec Pattern 1

Program

Special

Accel/Decel #1 – #4 Settings

This parameter enables a user-selected preprogrammed output profile that
controls the acceleration and deceleration pattern for the #1 Accel/Decel
parameter.

Settings:

0 — Linear
1 — S-Pattern 1
2 — S-Pattern 2

The figures below provide a profile of the available accel/decel patterns.

Direct Access Number — F502

Parameter Type — Selection List

Factory Default — Linear

Changeable During Run — Yes

Linear

acceleration and deceleration is the

default pattern and is used on most
applications.

S-pattern 1

is used for applications that require

quick acceleration and deceleration. This setting
is also popular for applications that require shock
absorption at the start of acceleration or
deceleration.

S-pattern 2

decreases the rate of change

above the base frequency.

F502