F350, F351, F352 – Toshiba H9 User Manual

Page 153: F353

Advertising
background image

H9 ASD Installation and Operation Manual

145

Acceleration Suspend Frequency

Program

Fundamental

Accel/Decel #1 Settings

When Enabled at

F349

, this parameter is used to set the frequency at which the

Acceleration Suspend function will activate.

During acceleration, this parameter sets the frequency at which acceleration
will stop and the motor will run at the setting of this parameter for the time
setting of

F351

.

Direct Access Number — F350

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — Max. Freq. (

F011

)

Units — Hz

Acceleration Suspend Time

Program

Fundamental

Accel/Decel #1 Settings

When Enabled at

F349

, this parameter is used to set the duration of activation

of the Acceleration Suspend function when initiated by reaching the
Acceleration Suspend Frequency setting (

F350

).

Once this parameter times out the acceleration rate will resume from the point
of suspension.

Direct Access Number — F351

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — Yes

Minimum — 0.0

Maximum — 10.0

Units — Seconds

Deceleration Suspend Frequency

Program

Fundamental

Accel/Decel #1 Settings

When Enabled at

F349

, this parameter is used to set the frequency at which the

Deceleration Suspend function will activate.

During deceleration, this parameter sets the frequency at which deceleration
will stop and the motor will run at the setting of this parameter for the time
setting of

F353.

Direct Access Number — F352

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — Max. Freq. (

F011

)

Units — Hz

Deceleration Suspend Time

Program

Fundamental

Accel/Decel #1 Settings

When Enabled at

F349

, this parameter is used to set the duration of activation

of the Deceleration Suspend function when initiated by reaching the
Deceleration Suspend Frequency setting (

F352

).

Once this parameter times out the deceleration rate will resume from the point
of suspension.

Direct Access Number — F353

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — Yes

Minimum — 0.0

Maximum — 10.0

Units — Seconds

F350

F353