CUSTOM AT COMMANDS

 

HSPA+ AT Commands Reference Guide 

154

 

Notes 

„

The alarm mode is indicated by status ON of hardware pin CTS and by status ON of pin DSR. The power saving 
status is indicated by a CTS ‐ OFF and DSR ‐ OFF status. The normal operating status is indicated by DSR ‐ ON. 

„

During the alarm mode the device does not make any network scan and does not register to any network. 
Therefore, the device cannot dial or receive any call or SM. The only command that can be issued to the module 
in this state is #WAKE. Every other command must not be issued during this state. 

Temperature Monitor   #TEMPMON 

Set command sets the behavior of the module internal temperature monitor. 

Read command reports the current parameter settings for #TEMPMON command in the format: 

#TEMPMON: <urcmode>,<action>[,<hyst_time>[,<GPIO>]] 

Test command reports the supported range of values for parameters <mod>, <urcmode>, <action>, <hyst_time> 
and <GPIO> 

Syntax 

Command 

Command type 

AT#TEMPMON=<mod>[,<urcmode>[,<action>[,<hyst_time>[,<GPIO>]]]] 

Set 

AT#TEMPMON? 

Read 

AT#TEMPMON=? 

Test 

Parameters and Values 

<mod> 

 

Sets the command parameters. 

Triggers the measurement of the module internal temperature, reporting the 
result in the format: 
#TEMPMEAS: <level>,<value> 
where: 
<level> ‐ Threshold level 
‐2 ‐ Extreme temperature lower bound. For details, see the Notes section.  
‐1 ‐ Operating temperature lower bound. For details, see the Notes section. 
0 ‐ Normal temperature 
1 ‐ Operating temperature upper bound. For details, see the Notes section. 
2 ‐ Extreme temperature upper bound. For details, see the Notes section. 
<value> ‐ Actual temperature expressed in Celsius degrees. 

<urcmode> 

<urcmode> ‐ URC presentation mode. 

0

 

Disables the presentation of the temperature monitor URC 

Enables the presentation of the temperature monitor URC, whenever the module 
internal temperature reaches either operating or extreme levels; the unsolicited 
message is in the format: 
#TEMPMEAS: <level>,<value> 
where: 
<level> and <value> are as before 

<action> 

Sum of integers, each representing an action to be done whenever the module 
internal temperature reaches either operating or extreme levels Default: 0
If <action> is not zero, it is mandatory to set the <hyst_time> parameter too. 
0..7 ‐ As a sum of: 