Notes, Call control, Hang up call +chup – Synaccess Networks NP-0801DTM User Manual

Page 47: Syntax, Select bearer service type +cbst

Advertising
background image

3GPP TS 27.007 AT COMMANDS 

 

 

47 

HSPA+ AT Commands Reference Guide

 

<T2> 

Response timer for the multiplexer control channel in units of ten milliseconds. 

2‐255 

Default: 30 (300 ms). Note: T2 must be longer than T1. 

<T3> 

Wake up response timer in seconds. 

1‐255 

Currently not supported, in case of read command 0 is returned. 

<k> 

Window size, for Advanced operation with Error Recovery options. 

1‐7 

Currently not supported. For read command, 0 is returned. 

Notes 

„

All the CMUX protocol parameters are fixed as defined in GSM07.10 and cannot be changed. 

„

Reference: 3GPP TS 27.007, 3GPP TS 27.010. 

Call Control 

Hang Up Call   +CHUP 

Execute command cancels all active and held calls, as well as multi‐party sessions, if running. 

Test command returns the OK result code. 

Syntax 

Command 

Command type 

AT+CHUP 

Execute 

AT+CHUP=? 

Test 

Notes 

„

Reference: 3GPP TS 27.007. 

Select Bearer Service Type   +CBST 

Set command sets the bearer service <name> with data rate <speed>, and the connection element <ce> to be 
used when data calls originate. This setting is also used during mobile terminated data call setup, in case of single 
numbering scheme calls. See +CSNS. 

Read command returns current value of the parameters <speed>, <name> and <ce>. 

Test command returns the supported range of values for the parameters. 

Syntax 

Command 

Command type 

AT+CBST=[<speed>[,<name>[,<ce>]]] 

Set 

AT+CBST? 

Read 

AT+CBST=? 

Test 