Syntax, Parameters and values, Select band #bnd – Synaccess Networks NP-0801DTM User Manual

Page 183

Advertising
background image

CUSTOM AT COMMANDS 

 

 

183 

HSPA+ AT Commands Reference Guide

 

Read command reports whether the ENS function is currently enabled or not, in the format: 

#ENS: <mode> 

Where <mode> represents values as described in the Parameters and Values section.  

Test command reports the available range of values for parameter <mode>. 

Syntax 

Command 

Command type 

AT#ENS=[<mode>] 

Set 

AT#ENS? 

Read 

AT#ENS=? 

Test 

Parameters and Values 

<mode> 

 

Disable ENS function. Default: 0

Enable ENS function. If AT#ENS=1 is issued, the following values are automatically 
set: 
At every next power‐up. Band GSM 850 and PCS enabled (AT#BND=3) 
Only at next power‐up. Automatic Band Selection enabled (AT#AUTOBND=2) only 
if the previous setting was equal to AT#AUTOBND=0 
Note: The new setting is available after next power‐up. 
Note: If ‘Four Band’ Automatic Band Selection is activated (AT#AUTOBND=2), at 
power‐up the value returned by AT#BND? might not be 3 if ENS function is 
enabled. 

Select Band   #BND 

Set command selects the current GSM and UMTS bands. This command only works if AT#AUTOBND is set to value 
of 0 or 1. 

Read command returns the current selected band in the format: 

#BND: <band> , <UMTS band> 

Test command returns the supported range of values of parameters <band> and < UMTS band>. 

Syntax 

Command 

Command type 

AT#BND=[<band> [, <UMTS band>]] 

Set 

AT#BND? 

Read 

AT#BND=? 

Test 

Advertising