Notes, Syntax, Parameters and values – Synaccess Networks NP-0801DTM User Manual

Page 200

Advertising
background image

 

CUSTOM AT COMMANDS

 

HSPA+ AT Commands Reference Guide 

200

 

#TCPATRUN: <DISCONNECT>
Unsolicited is dumped on the instance that requested the service activation. 

<timeout> 

Define in minutes the maximum time for a command execution. If timeout 
expires the module is rebooted. Default: 5 minutes. Range: 1‐5. 

<authMode> 

Determines the authentication procedure in server mode. 

When connection is up, username and password (in this order, each followed by a 
carriage return) must be sent to the module before the first AT command. 
Default: 0

When connection is up, the user receives a request for username and, if 
username is correct, a request for password. Then a message of ”Login 
successful” closes authentication phase. 

Notes 

„

The current settings are stored in non‐volatile memory. 

„

To start the service automatically when the module is powered‐on, you must set the automatic PDP context 
activation. See AT#SGACTCFG command. 

„

The set command returns ERROR if the command AT#TCPATRUNL? returns 1 as <mod> parameter or the 
command AT#TCPATRUND? returns 1 as <mod> parameter. 

TCP Run AT Service in Listen Server Mode   #TCPATRUNL 

Set command enables or disables the TCP AT RUN service in server mode. When this service is enabled, the 
module tries to put itself in TCP listen state. 

Read command returns the current settings of <mode> and the value of <stat> in the format: 

#TCPATRUNL: <mod>,<stat> 

where: 

<stat> 

Connection status. 

Not in listen. 

In listen, or active.  

Test command returns the supported values for the parameters 

Syntax 

Command 

Command type 

AT#TCPATRUNL=<mod> 

Set 

AT#TCPATRUNL? 

Read 

AT#TCPATRUNL=? 

Test 

Parameters and Values 

<mod> 

 

Service disabled. 

Service enabled. 

Notes 

„

If SMSATRUN is active on the same instance—see AT#TCPATRUNCFG—the command returns ERROR. 

Advertising