Parameters and values, Notes, Connection completion time-out s7 – Synaccess Networks NP-0801DTM User Manual

Page 42: Syntax, Delay to dtr off s25, Connection completion time‐out s7

Advertising
background image

 

HAYES COMPLIANT AT COMMANDS 

 

HSPA+ AT Commands Reference Guide 

42 

 

Parameters and Values 

<char> 

Command line editing character (decimal ASCII). 

0‐127 

Default: 8. (ASCII BS). 

Notes 

„

Reference: V.25ter. 

Connection Completion Time‐Out   S7 

Set command sets the amount of time, in seconds, that the device allows between either answering a call 
(automatically or by A command) or completion of signaling of call addressing information to network (dialing), 
and establishment of a connection with the remote device. 

Read command returns the current value of S7 parameter. The format of the numbers in output is always 3 digits, 
left‐filled with 0s. 

Syntax 

Command 

Command type 

ATS7=[<tout>] 

Set 

ATS7? 

Read 

Parameters and Values 

<tout> 

Number of seconds.

 

1‐255  

Default: 60

Notes 

„

Reference: V.25ter. 

S12 

This command will be defined for a future release. The default for this command is 050. 

Delay to DTR Off   S25 

Set command defines the amount of time, in hundredths of second, that the device ignores the DTR for taking the 
action specified by command &D. 

Read command returns the current value of S25 parameter. The format of the numbers in output is always 3 
digits, left‐filled with 0s. 

Syntax 

Command 

Command type 

ATS25=[<time>] 

Set 

ATS25? 

Read 

Parameters and Values 

<time> 

Expressed in hundredths of a second. 

0‐255 

Default: 5

Note:

 The delay is effective only if its value is greater than 5. Command not yet 

Advertising