V.250 at commands, Generic modem control, Set to factory-defined configuration &f – Synaccess Networks NP-0801DTM User Manual

Page 24: Syntax, Parameters and values, Notes, Soft reset z, Set to factory‐defined configuration &f

Advertising
background image

 

HAYES COMPLIANT AT COMMANDS 

 

HSPA+ AT Commands Reference Guide 

24 

 

V.250 AT Commands 

Generic Modem Control 

Set to Factory‐Defined Configuration   &F 

Execute this command to set the configuration parameters to default values specified by the manufacturer. This 
includes hardware configuration switches and other manufacturer‐defined criteria. 

Syntax 

Command 

Command type 

AT&F[<value>] 

Set 

Parameters and Values 

<value> 

Hardware version, a string of no more than 31 characters. 

0  

Only the factory profile base section parameters are set to default values. 

1  

Full factory profile restored, that is, the factory profile base section and the 
extended section are restored. 

Notes 

„

If parameter <value> is omitted, the command has the same behavior as AT&F0. 

„

Reference: V.25ter. 

Soft Reset   Z 

Execute this command to the base section of the specified user profile and the extended section of the default 
factory profile. 

Syntax 

Command 

Command type 

ATZ[<n>] 

 

Parameters and Values 

<n> 

Hardware version, a string of no more than 31 characters. 

0‐1  

User profile number. 

Notes 

„

Any call in progress is terminated. 

„

If parameter <n> is omitted, the command has the same behavior as ATZ0. 

„

Reference: V.25ter. 

Advertising