CUSTOM AT COMMANDS

 

HSPA+ AT Commands Reference Guide 

208

 

<mode>

 

 

Disable the single event monitoring. Default: 0

Enable the single event monitoring. 

<paramType> 

Numeric parameter indicating the type of parameter contained in <param>.  
0 value indicates that <param> contains the AT command string to execute when 
the related event has occurred. Other values depend from the type of event. 

<param> 

Numeric or string value depending on the value of <paramType> and on the type 
of event. 

If <paramType> is 0, then <param> is a string containing the AT command: 

„

It has to be enclosed between double quotes 

„

It has to start with the 2 characters AT (or at). 

„

If the string contains the character ”, then it has to be replaced with the 3 characters \22. 

„

The maximumstring length is 96 characters. 

„

If it is an empty string, the AT command is erased. 

„

If <label> is VBATT, <paramType> can assume values in the range 0 ‐ 2. 

ƒ

if <paramType> = 1, <param> indicates the battery voltage threshold in the range 0 – 500, where one unit 
corresponds to 10 mV (therefore 500 corresponds to 5 V). Default: 0

ƒ

if <paramType> = 2, <param> indicates the time interval in seconds after that the voltage battery under the 
value specified with <paramType> = 1 causes the event. The range is 0 – 255. Default: 0

„

If <label> is DTR, <paramType> can assume values in the range 0 ‐ 2. 

ƒ

if <paramType> = 1, <param> indicates the status high or low under monitoring. The values are 0 (low) and 1 
(high). Default: 0

ƒ

if <paramType> = 2, <param> indicates the time interval in seconds after that the DTR in the status specified 
with <paramType> = 1 causes the event. The range is 0 – 255. Default: 0 

„

If <label> is ROAM, <paramType> can assume only the value 0. The event under monitoring is the roaming state. 

„

If <label> is CONTDEACT, <paramType> can assume only the value 0. The event under monitoring is the context 
deactivation. 

„

If <label> is RING, <paramType> can assume values in the range 0 ‐ 1. 

ƒ

If <paramType> = 1, <param> indicates the numbers of call rings after that the event occurs. The range is 1‐
50. Default: 1

„

If <label> is STARTUP, <paramType> can assume only the value 0. The event under monitoring is the module 
start‐up. 

„

If <label> is REGISTERED, <paramType> can assume only the value 0. The event under monitoring is the network 
registration (to home network or in roaming) after the start‐up and the SMS ordering. 

„

If <label> is GPIOX, <paramType> can assume values in the range 0 ‐ 3. 

ƒ

if <paramType> = 1, <param> indicates the GPIO pin number; supported range is from 1 to a value that 
depends on the hardware. Default: 1

ƒ

if <paramType> = 2, <param> indicates the status high or low under monitoring. The values are 0 (low) and 1 
(high). Default: 0

ƒ

if <paramType> = 3, <param> indicates the time interval in seconds after that the selected GPIO pin in the 
status specified with <paramType> = 1 causes the event. The range is 0 – 255. Default: 0. 

„

If <label> is ADCH1, <paramType> can assume values in the range 0 ‐ 3. 