3GPP TS 27.007 AT COMMANDS 

 

 

87 

HSPA+ AT Commands Reference Guide

 

Parameters and Values 

<time> 

Current alarm time as quoted string. 

“” 

Empty string. Deletes the current alarm and resets all the +CALA 
parameters to the default configuration. 

"hh:mm:ss±zz" 

Format used only when issuing +CALA with parameter <recurr> too 

"yy/MM/dd,hh:mm:ss±zz" 

Generic format: it’s the same as defined for +CCLK. 

<n> 

Index of the alarm. 

The only value supported is 0 

<type> 

Alarm behavior type 

Reserved for other equipment use 

The module simply wakes up fully operative as if the ON/OFF 
button had been pressed. If the device is already ON at the alarm 
time, then it does nothing. Default . 

The module wakes up in "alarm mode" if at the alarm time it was 
off, otherwise it remains fully operative. In both cases the module 
issues an unsolicited code every 3 seconds.  
+CALA: <text> 
where <text> is the +CALA optional parameter previously set. 
The device keeps on sending the unsolicited code every 3 seconds 
until a #WAKE command is received or a 90 seconds timer expires. 
If the device is in "alarm mode" and it does not receive the #WAKE 
command within  90 seconds then it shuts down. 

The module wakes up in "alarm mode" if at the alarm time it was 
off, otherwise it remains fully operative. In both cases the module 
starts playing the alarm tone on the selected path for the ringer. 
See command #SRP. 
The device keeps playing the alarm tone until a #WAKE command is 
received or a 90 second time‐out occurs. If the device is in "alarm 
mode" and it does not receive the #WAKE command within 90 
seconds then it shuts down. 

The module wakes up in "alarm mode" if at the alarm time it was 
off, otherwise it remains fully operative. In both cases the module 
brings the pin GPIO6 high, provided its <direction> is set to alarm 
output, and keeps it in this state until a #WAKE command is 
received or a 90 seconds timer expires. If the device is in "alarm 
mode" and it does not receive the #WAKE command within 90 
seconds then it shuts down. 

The module makes both the actions as for type=2 and <type>=3. 

The module makes both the actions as for type=2 and <type>=4. 

The module makes both the actions as for type=3 and <type>=4. 

The module wakes up in "alarm mode" if at the alarm time it was 
off, otherwise it remains fully operative. In both cases the module 
sets High the RI output pin. The RI output pin remains High until 
next #WAKE issue or until a 90 second timer expires. If the device is 
in "alarm mode" and it does not receive the #WAKE command 
within 90 seconds. After that it shuts down. 

<text> 

Unsolicited alarm code text string. It has meaning only if <type> is 
equal to 2, 5 or 6. 