7 holding brake configuration, Holding brake configuration, Commissioning – Lenze ECSCSxxx User Manual

Page 102

Advertising
background image

Commissioning

Holding brake configuration

6

l

102

EDBCSXS064 EN 4.0

6.7

Holding brake configuration

I

Tip!

If you use a motor without a holding brake, you can skip this chapter.

In the GDC, the parameters or codes to be set can be found in the parameter menu under
Short setup

W Brake:

ECSXA303

Fig. 6−5

GDC view: Short setup of the holding brake

Code

Name

Description

C0195

Brake closing
time/engagement
time

The time required for closing the holding brake.

l

When Ctrl1.Bit7 = 0 (FALSE), the brake is closed.

l

Only after this time has elapsed, the controller inhibit is activated.

C0196

Brake opening
time/disengagement
time

The time required for opening the holding brake.

l

During the time set the drive generates the torque set under C0244
against the holding brake.

l

If an actual speed higher than the value in C0472/10 is detected before the
brake opening time (C0196) has expired, the drive can immediately change
to speed−controlled operation.

C0244

Holding torque

Holding torque of the drive against the holding brake

l

100 %

¢ value of C0057

C0472/10 FCODE analog [%]

Speed threshold for closing the brake:

l

Only if the actual speed value has fallen below the speed threshold, the
"close brake" signal is output.

l

This code refers to the maximum speed set in C0011.

Note: Enter a value > 0 so that the brake can be opened.

C0472/11 FCODE analog [%]

Value/direction of the torque against the holding brake.