Appendix – Lenze ECSCSxxx User Manual

Page 388

Advertising
background image

Appendix

Code table

13

l

388

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0444

Status of the digital outputs
Only display

1 DIS: DIGOUT

0

1 Status of the digital output

X6/DO1

2 DIS: DIGOUT

Relay control status

[C0469] Fct STP key

2

Function of the STOP key of the
keypad
Must not be changed if the
"STOP" key is pressed!

0

Inactive

Without function

1

Controller inhibit (CINH)

2

Quick stop (QSP)

C0470

Freely configurable code for
digital signals
Hexadecimal value is bit−coded.

^ 309

1 FCODE 8bit

0

00

{hex}

FF C0470/1 = C0471, bit 0 ... 7

2 FCODE 8bit

0

C0470/2 = C0471, bit 8 ... 15

3 FCODE 8bit

0

C0470/3 = C0471, bit 16 ... 23

4 FCODE 8bit

0

C0470/4 = C0471, bit 24 ... 31

C0471 FCODE 32bit

0

Hexadecimal 32−bit
interpretation of C0470

^ 309

0

{1}

4294967295

C0472 FCODE analog

Freely configurable code for
relative analog signals

^ 309

1

0.0

−199.99

{0.01 %}

199.99 FCODE_bC472_1_a

2

0.0

FCODE_bC472_2_a

3

100.0

FCODE_bC472_3_a

4

0.0

FCODE_bC472_4_a

...

...

...

20

0.0

FCODE_bC472_20_a

C0473

Freely configurable code for
absolute analog signals

^ 309

1 FCODE abs

1

−32767

{1}

32767

2 FCODE abs

1

3 FCODE abs

0

... ...

...

10 FCODE abs

0

C0474

Freely configurable code for
phase signals

^ 309

1 FCODE PH

0

−2147483647

{1}

2147483647

... ...

...

5 FCODE PH

0

C0475

Freely configurable code for
phase difference signals

^ 309

1 FCODE DF

0

−16000

{1 rpm}

16000

2 FCODE DF

0