DFOUT (master frequency output)

12

l

306

EDBCSXS064 EN 4.0

Configuring the master frequency output signal

)

Note!

Dependent on the system, the master frequency output X8 has a delay time of
T

d

= 1 ms.

Via code C0540 you configure the type of the master frequency output signal:

C0540 = 0

Output of an analog signal

Function

The input signal DFOUT_nOut_vis interpreted as an analog signal [%] and is output as a
frequency signal on the master frequency output X8.

Scaling

100 %

º (INT)16384 º C0011 (n

max)

Transfer function

f [Hz]

+ DFOUT−Out [%] @ C0030

100 @

C0011 (n

max

)

60

DFOUT−ln_v

+ f [Hz] @ 60

C0030 @

2

14

15000

Example

l

DFOUT_nOut_v = 50 %

l

C0030 = 3, this corresponds to a number of increments of 2048 increments/revolution

l

C0011 = 3000 rpm

f [Hz]

+ 50 % @ 2048

100 @

3000

60

+ 51200 Hz

C0540 = 1

Output of a speed signal

Function

The input signal DFOUT_nOut_vis interpreted as a speed signal [rpm] and is output as a
frequency signal on the master frequency output X8.

Scaling

15000 rpm

º (INT)16384

Transfer function

f [Hz]

+ DFOUT−Out [rpm] @ C0030

60

Example

l

DFOUT_nOut_v = 3000 rpm

l

C0030 = 3, this corresponds to a number of increments of 2048 increments/revolution

f [Hz]

+ 3000 rpm @ 2048

60

+ 102400 Hz

C0540 = 2

Encoder simulation of the resolver with zero track in resolver position

Function

l

The function is used if a resolver is connected to X7.

l

The encoder constant for output X8 is set in C0030.

l

The output of the zero pulse with reference to the rotor depends on how the resolver is
mounted to the motor.

l

The zero pulse can be shifted by +360 ° via code C0545 (65536 inc = 360 °).

Signal sequence

Track CW rotation

CCW rotation

B

B

A

A

Z

Z

A

If the input values are positive,
track A leads by 90º.

If the input values are
negative, track A lags by 90º.

B

˘

˘

Signal sequence with phase shift (CW
rotation)

ƒ

The output signal corresponds to the message of an incremental encoder:
– Track A, B and, if selected, zero track as well as the corresponding inverted tracks

are output with tracks shifted by 90 degrees.

– The levels are TTL compatible.

ƒ

The zero track is output in accordance with the function set in code C0540.