Commissioning

Configuring the digital inputs and outputs

Change of the terminal assignment

6

l

125

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

For possible signals see "selection list − digital
signals"

^ 428

[C7511]

Selection of the signal source for
the digital input signals of the
"Torque" function block

1 TorqueIn−dig

1000

0 (FALSE, not assigned)

CW rotation (TORQUE−RLQ.Cw)

^ 350

2 TorqueIn−dig

1000

0 (FALSE, not assigned)

CCW rotation
(TORQUE−RLQ.CCw)

3 TorqueIn−dig

1000

0 (FALSE, not assigned)

Setting of the torque setpoint
integrator to 0 along the
adjusted ramps
(TORQUE−NSET.Rfg0)

^ 351

4 TorqueIn−dig

1000

0 (FALSE, not assigned)

Activation of the motor holding
brake (TORQUE−BRK.SetBrake)

^ 360

5 TorqueIn−dig

1000

0 (FALSE, not assigned)

Setting of quick stop
(TORQUE−QSP.Set1)

^ 354

6 TorqueIn−dig

1000

0 (FALSE, not assigned)

Setting of quick stop
(TORQUE−QSP.Set2)

7 TorqueIn−dig

1000

0 (FALSE, not assigned)

Source for the integral−action
component of the controller
(TORQUE−MCTRL.ILoad)

8 TorqueIn−dig

1000

0 (FALSE, not assigned)

Keeping (freezing) the torque
setpoint integrator to the current
value (TORQUE-NSET.RfgStop)

9 TorqueIn−dig

1000

0 (FALSE, not assigned)

Inversion of additional torque
setpoint (TORQUE−MAddInv)

For possible signals see "selection list − digital
signals"