Function library

AIF2Out

12

l

260

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C6155 AIF2PdoMap

0

Assignment of the 8 byte user
data of the AIF2Out function
block to the fieldbus module

^ 258

0

W0=Int W1=Int

Byte 1, byte 2 = AIF2Out−W0

Byte 3, byte 4 = AIF2Out−W1

Byte 5, byte 6 = AIF2Out−W2

Byte 7, byte 8 = AIF2Out−W3

1

W0 / W1=Dint

Byte 1, byte 2 = AIF2Out−W0/W1

Byte 3, byte 4 = AIF2Out−W0/W1

Byte 5, byte 6 = AIF2Out−W2

Byte 7, byte 8 = AIF2Out−W3

User data

The eight bytes of user data to the fieldbus module can be assigned with

ƒ

analog signals (16 bits).

ƒ

phase signals (32 bits).

The switch C6155 is used to assign the eight bytes of user data to the fieldbus module:

Value in

C6155

User data

Byte 1, 2

Byte 3, 4

Byte 5, 6

Byte 7, 8

0

AIF2Out−W0

AIF2Out−W1

AIF2Out−W2

AIF2Out−W3

16 bits (C6131/5)

16 bits (C6131/6)

16 bits (C6131/7)

16 bits (C6131/8)

1

AIF1Out−W0/W1

AIF2Out−W2

AIF2Out−W3

32 bits (C6151/2)

16 bits (C6131/7)

16 bits (C6131/8)