7 rfi filters, Rfi filters, Appendix – Lenze ECSCSxxx User Manual

Page 468

Advertising
background image

Appendix

Overview of accessories

13

l

468

EDBCSXS064 EN 4.0

13.5.7

RFI filters

According to the application, different measures for reducing the mains current and for
radio interference suppression are required on the supply side for servo systems. As a rule,
these measures are not mandatory, but protect the universal application of a servo system.

Lenze offers a built−on filter for each power supply module for the interference level A. The
RFI filters are designed for the ECS power supply module assigned and up to 10 axes with
a motor cable length of 25 m each (Lenze system cable). The interference level A is
observed as long as the motor cable length per axis module is 25 m at a maximum (Lenze
sytem cables) and the number of the ECS axis modules is maximally 10.

RFI filter type

ECS power supply module type

ECSZZ020X4B

ECSxE012

ECSxE020

ECSZZ040X4B

ECSxE040

Type of RFI filter

U

[V]

I

[A]

P

loss

[W]

Weight [kg]

ECSZZ020X4B

3/PE AC 500 V

at 50 ... 60 Hz

16

6.2

3.0

ECSZZ040X4B

32

9.3

U

Rated mains voltage

I

Rated mains current

P

loss

Power loss

Advertising