4 effecting rotor position adjustment, Effecting rotor position adjustment, Commissioning – Lenze ECSCSxxx User Manual

Page 151

Advertising
background image

Commissioning

Operation with motors from other manufacturers

Effecting rotor position adjustment

6

l

151

EDBCSXS064 EN 4.0

6.15.4

Effecting rotor position adjustment

)

Note!

Resolver / absolute value encoder with Hiperface® interface

ƒ

If the rotor zero phase is not known, the rotor position only has to be
adjusted once during commissioning.

ƒ

For multi−turn absolute value encoders, the traversing range must be within
the display range of the encoder (0 ... 4095 revolutions) if the traversing
range is limited.

TTL incremental encoder / sin/cos encoder with zero track

ƒ

If these encoder types are used for the operation of synchronous motors, the
rotor position must be adjusted every time the low−voltage supply is
switched on.

The rotor position must be adjusted if:

ƒ

A motor from another manufacturer is connected to the controller.

ƒ

Another encoder has been mounted subsequently.

ƒ

A defective encoder has been replaced.

The rotor position can only be adjusted if:

ƒ

The resolver is polarised correctly.

ƒ

The current controller has been adjusted.

The GDC contains the parameters or codes to be set on the parameter menu under
Motor/Feedb.

W Rotor position adjustment:

ECSXA304

Fig. 6−21

GDC view: Short setup of the feedback system

Advertising
This manual is related to the following products: