Monitoring of the synchronisation (sync time slot), Configuration – Lenze ECSCSxxx User Manual

Page 181

Advertising
background image

Configuration

Configuring MotionBus/system bus (CAN)

Monitoring of the synchronisation (sync time slot)

8

l

181

EDBCSXS064 EN 4.0

8.1.7

Monitoring of the synchronisation (sync time slot)

Sync-window

Sync cycle

Sync cycle

Sync-signal

ECSXA474

Fig. 8−3

"Time slot" for the LOW−HIGH edges of the sync signal

)

Note!

A jitter (

179) up to ±200 ms on the LOW−HIGH edges of the sync signal is

permissible. The amount of the jitter has an impact on the parameterisation of
the "time slot".

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C1123 Sync window

0.010

Synchronisation window

^ 181

0.000

{0.001 ms}

6.500

CAN sync response

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0366 Sync Response

1

CAN sync response for interface
X4 (CAN)
The value "1" should always be
set!

^ 181

0

No response

1

Response

Advertising