Function library

AIF3Out

12

l

265

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C6156 AIF3PdoMap

0

Assignment of the 8 byte user
data of the AIF3Out function
block to the fieldbus module

^ 263

0

W0=Int W1=Int

Byte 1, byte 2 = AIF3Out−W0

Byte 3, byte 4 = AIF3Out−W1

Byte 5, byte 6 = AIF3Out−W2

Byte 7, byte 8 = AIF3Out−W3

1

W0 / W1=Dint

Byte 1, byte 2 = AIF3Out−W0/W1

Byte 3, byte 4 = AIF3Out−W0/W1

Byte 5, byte 6 = AIF3Out−W2

Byte 7, byte 8 = AIF3Out−W3

User data

The eight bytes of user data to the fieldbus module can be assigned with

ƒ

analog signals (16 bits).

ƒ

phase signals (32 bits).

The switch C6156 is used to assign the eight bytes of user data to the fieldbus module:

Value in

C6156

User data

Byte 1, 2

Byte 3, 4

Byte 5, 6

Byte 7, 8

0

AIF3Out−W0

AIF3Out−W1

AIF3Out−W2

AIF3Out−W3

16 bits (C6131/9)

16 bits (C6131/10)

16 bits (C6131/11)

16 bits (C6131/12)

1

AIF3Out−W0/W1

AIF3Out−W2

AIF3Out−W3

32 bits (C6151/3)

16 bits (C6131/11)

16 bits (C6131/12)