14 quick stop (qsp), Commissioning – Lenze ECSCSxxx User Manual

Page 144

Advertising
background image

Commissioning

Quick stop (QSP)

6

l

144

EDBCSXS064 EN 4.0

6.14

Quick stop (QSP)

By means of the quick stop function, the drive is braked to standstill within a set
deceleration time (C0105).

Quick stop (QSP) is activated by the following signal sources:

Configuration/operating mode

QSP active if

Lenze setting

During mains connection

l

X6/DI1 and DI2 = HIGH
or

l

X6/DI1 and DI2 = LOW

During operation

l

X6/DI1 and DI2 = LOW
QSP is recognised device−internally if a LOW signal is
applied to X6/DI1 and DI2 for more than 2 ms.

Speed control ("Speed")

l

SPEED−QSP.Set1 (C7411/17) = TRUE
or

l

SPEED−QSP.Set2 (C7411/18) = TRUE

(further information:

^ 338)

Torque control ("Torque"):

l

TORQUE−QSP.Set1 (C7511/17) = TRUE
or

l

TORQUE−QSP.Set2 (C7511/18) = TRUE

(further information:

^ 358)

The deceleration time for the brake application is set via C0105 in the GDC parameter
menu under

ƒ

Short setup

W Speed (for speed control).

ƒ

Short setup

W Torque (for torque control).

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0042 DIS: QSP

Quick stop status (QSP)
Only display

^ 297

^ 144

0

QSP not active

1

QSP active

C0105 QSP Tif

0.0

Deceleration time for quick stop
(QSP)

^ 297

^ 144

0.000

{0.001 s}

999.999 Relating to speed variation n

max

(C0011) ...0 rev./min.

Advertising
This manual is related to the following products: