Appendix – Lenze ECSCSxxx User Manual

Page 448

Advertising
background image

Appendix

Communication with MotionBus/system bus (CAN)
Process data transfer

13

l

448

EDBCSXS064 EN 4.0

Interface

PDOs

RPDO: to ECS module
TPDO: from ECS module

Availability in ECS modules

ECSxE

ECSxS

ECSxP

ECSxM ECSxA

X1

Automation interface (AIF)

RPDO

AIF1_IN

˘

ü

V3.0 or

higher

V3.0 or

higher

ü

AIF2_IN

˘

ь

˘

˘

ь

AIF3_IN

˘

ь

˘

˘

ь

TPDO

AIF1_OUT

˘

ü

V3.0 or

higher

V3.0 or

higher

ü

AIF2_OUT

˘

ь

˘

˘

ь

AIF3_OUT

˘

ь

˘

˘

ь

X4

ECSxS/P/M: MotionBus (CAN)
ECSxA/E: System bus (CAN)

RPDO

CAN1_IN

ь

ь

ь

ь

ь

CAN2_IN

˘

ь

ь

˘

ь

CAN3_IN

ь

ь

ь

˘

ь

TPDO

CAN1_OUT

ь

ь

ь

ь

ь

CAN2_OUT

ь

1)

ь

ь

˘

ь

CAN3_OUT

ь

ь

ь

˘

ь

X14

System bus (CAN)
Interface is not available for ECSxE.

RPDO

CANaux1_IN

˘

˘

ь

˘

ь

CANaux2_IN

˘

˘

ь

˘

ь

CANaux3_IN

˘

˘

˘

˘

ü

TPDO

CANaux1_OUT

˘

˘

ь

˘

ь

CANaux2_OUT

˘

˘

ь

˘

ь

CANaux3_OUT

˘

˘

˘

˘

ü

1) ECSxE from V5.0: CAN2_OUT (Diagnostic PDO)

)

Note!

Power supply module ECSxE
In case of the ECSxE power supply module, the PDOs CAN1_IN/OUT and
CAN3_IN/OUT cannot be used simultaneously. The PDOs to be used are
selected via C0360.

ƒ

The process data objects are integrated into the ECSxS... axis modules in the form of
function blocks (

^ 247).

ƒ

In the function blocks the user data is converted to corresponding signal types for
further use.

13.4.3.2

Structure of the process data

The process data telegrams have a maximum user data length of eight bytes each.

Process data input telegram (RPDO)

ƒ

The process data input telegram transmits control information to the controller.

ƒ

The control word is transmitted in byte 1 and 2 of the user data.

Advertising
This manual is related to the following products: