Function library – Lenze ECSCSxxx User Manual

Page 281

Advertising
background image

Function library

CAN1Out

12

l

281

EDBCSXS064 EN 4.0

User data

The eight bytes of user data to the MotionBus (CAN) can be assigned with

ƒ

digital signals (1 bit).

ƒ

analog signals (16 bits).

ƒ

phase signals (32 bits).

The switch C6254 is used to assign the eight bytes of user data to the MotionBus (CAN):

Value in

C6254

User data

Byte 1, 2

Byte 3, 4

Byte 5, 6

Byte 7, 8

0

CAN1Out−DctrlStat

CAN1Out−W1

CAN1Out−W2

CAN1Out−W3

16 bits (C6231/1)

16 bits (C6231/2)

16 bits (C6231/3)

16 bits (C6231/4)

1

CAN1Out−DctrlStat

CAN1Out−W1

CAN1Out−W2/W3

16 bits (C6231/1)

16 bits (C6231/2)

32 bits (C6251/1)

2

CAN1Out−DctrlStat

CAN1Out−W1

CAN1Out−W2

CAN1Out−Bit0 ... 15

16 bits (C6231/1)

16 bits (C6231/2)

16 bits (C6231/3)

1 bit (C6211/1 ... 15)

3

CAN1Out−DctrlStat

CAN1Out−W1

CAN1Out−Bit0 ... 15

CAN1Out−W3

16 bits (C6231/1)

16 bits (C6231/2)

1 bit (C6211/1 ... 15)

16 bits (C6231/4)

4

CAN1Out−DctrlStat

CAN1Out−Bit0 ... 15

CAN1Out−W2

CAN1Out−W3

16 bits (C6231/1)

1 bit (C6211/1 ... 15)

16 bits (C6231/3)

16 bits (C6231/4)

5

CAN1Out−DctrlStat

CAN1Out−Bit0 ... 15

CAN1Out−W2/W3

16 bits (C6231/1)

1 bit (C6211/1 ... 15)

32 bits (C6251/1)

)

Note!

You can use byte 1 and byte 2 to transfer the status word from the DCTRL
function block (

294) to the MotionBus (CAN).

Advertising