Code table

13

l

387

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C0421] Encoder volt

0

Encoder voltage

^ 301

^ 106

^ 113

0

5.0 V

Sets C0419 = 0 ("common") if the
value is altered.

1

5.6 V

2

6.3 V

3

6.9 V

4

7.5 V

5

8.1 V

C0426 DIS: In

Signal at DFIN input
Only display

^ 301

−32767

{1 rpm}

32767

[C0427] Enc. signal

0

Function of the master frequency
input signals on X8 (DFIN)

^ 301

^ 106

^ 113

0

2−phase

1

A: speed
B: direction

2

A or B: speed or direction

C0428 DFIN TP sel.

0

DFIN touch probe signal source

0

Zero pulse of position encoder (C0490) X7/X8

1

Touch probe input TP1

X6/DI1

2

Zero pulse of digital frequency input

X8

C0429 TP1 delay

0

DFIN dead time compensation
TP1 (DI1)

−32767

{1 inc}

32767

C0431 DFIN TP Edge

0

DFIN touch probe TP1 edge
(for touch probe via digital input
X6/DI1 (C0428 = 1))

0

Rising edge TP1

1

Falling edge TP1

2

Rising and falling edge TP1

3

Switched off

C0443 DIS: DIGIN

Signal status of the digital inputs
on X6 after consideration of the
polarity set under C0114.
Only display

^ 307

0

{1}

255

Bit 0

DIGIN1

X6/DI1

^ 121

Bit 1

DIGIN2

X6/DI2

Bit 2

DIGIN3

X6/DI3

Bit 3

DIGIN4

X6/DI4

Bit 4

DIGIN_safe_standstill

X6/SI2
0: Pulse inhibit is active
1: Pulse inhibit is inactive

^ 71

Bit 5

Free

Bit 6

DIGIN_CInh

X6/SI1
0: Controller is inhibited (CINH)
1: Controller is enabled

^ 71

Bit 7

Free