Optimising the drive behaviour after start

Speed controller adjustment

6

l

155

EDBCSXS064 EN 4.0

Parameter setting

ƒ

Set the proportional gain (V

pn

) via C0070:

– Enter approx. 50 % of the speed setpoint (100 % = 16384 = n

max

).

– Increase C0070 until the drive becomes instable (pay attention to engine noises).
– Reduce C0070 until the drive runs stable again.
– Reduce C0070 to approx. half the value.

)

Note!

For speed control ("Speed"):
The proportional gain (V

p

) can be altered via SPEED−MCTRL.NAdapt (C7431/7):

ƒ

V

p

= SPEED−MCTRL.NAdapt[%] x C0070

ƒ

If SPEED−MCTRL.NAdapt is not assigned, the following applies: V

p

= 100 %,

C0070 = C0070

For torque control ("Torque"):
The proportional gain (V

p

) can be altered via TORQUE−MCTRL.NAdapt

(C7531/7):

ƒ

V

p

= TORQUE−MCTRL.NAdapt[%] x C0070

ƒ

If TORQUE−MCTRL.NAdap is not assigned, the following applies: V

p

= 100 %,

C0070 = C0070

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0070 Vp speedCTRL

3.0

Proportional gain of speed
controller (V

pn

)

^ 154

0.00

{ 0.01}

127.99

ƒ

The reset time (T

nn

) is set via C0071:

– Reduce C0071 until the drive becomes instable (pay attention to engine noises).
– Increase C0071 until the drive runs stable again.
– Increase C0071 to approx. the double value.

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0071 Tn speedCTRL

24.0

Reset time − speed controller
(T

nn

)

^ 154

1.0

{0.5 ms}

6000.0

Advertising