Code table

13

l

400

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C2120 AIF: Control

0

AIF−CAN: control word

0

{1}

255 Binary interpretation reflects bit

states

0

No command

Note: The MSB (bit 7) of the
control word automatically
changes its state with every
access to the code. Observe this
when interpreting the data!

1

Read XCAN codes + reinitialisation

2

Read XCAN code

10

Read XCAN C2356/1 ... 4

11

Read XCAN C2357

12

Read XCAN C2375

13

Read XCAN C2376 ... C2378

14

Read XCAN C2382

255

Not assigned

C2121 AIF:State

AIF status
More detailed information can
be found in the documentation
of the plugged−in fieldbus
module.
Read only

1

{1}

255 Binary interpretation reflects bit

states.

Bit 0

XCAN1_IN monitoring time

Bit 1

XCAN2_IN monitoring time

Bit2

XCAN3_IN monitoring time

Bit3

XCAN bus off

Bit4

XCAN operational

Bit5

XCAN pre−operational

Bit 6

XCAN warning

Bit 7

Assigned internally

C2130 FileNameAdd

Da

Symbolic data name

Information on the additional
data that have been transmitted
together with the application
program.
Only display

C2131 Type AddData

Specification identification of the data

C2132 VersionAddDa

ta

Data version

C2133 TimeStamp

Time stamp of the data

C2350 XCAN address

1

Node address XCAN
(AIF interface X1)

1

{1}

63

C2351 XCAN baud

rate

0

Baud rate XCAN
(AIF interface X1)

0

500 kbps

1

250 kbit/sec

2

125 kbits/s

3

50 kbps

4

1000 kbit/s

C2352 XCAN mst

0

Establish XCAN master
operation.
(AIF interface X1)

0

Slave

1

Master