3 speed control with setpoint via motionbus (can), Speed control with setpoint via motionbus (can), Commissioning – Lenze ECSCSxxx User Manual

Page 132

Advertising
background image

Commissioning

Selecting the operating mode/control structure
Speed control with setpoint via MotionBus (CAN)

6

l

132

EDBCSXS064 EN 4.0

6.10.3

Speed control with setpoint via MotionBus (CAN)

Configuration C3005 = 1005

)

Note!

ƒ

Use the "input assistant for motor data" of the GDC for setting the motor
data (

^ 100).

ƒ

Reading the data via CAN1_In requires an external sync signal (from the
master control).

Set the following codes:

Code

Meaning

Further
information

DC−bus voltage thresholds and charge relay function

C0173 = x

DC−bus voltage thresholds

^ 99

C0175 = x

Charge relay function
(when using an ECS supply module: C0175 = 3)

^ 98

Maximum motor current

C0022 = x [A]

Maximum motor current (I

max

)

Controller configuration and feedback system

C3005 = 1005

Speed control with setpoint via MotionBus (CAN)

^ 126

C0495 = x

Feedback system

^ 103

Speed setpoint settings

C0011 = x [rpm]

Maximum speed

^ 333

C0012 = x [s]

Acceleration time

^ 327

C0013 = x [s]

Deceleration time

C0105 = x [s]

Quick stop deceleration time

^ 338

Application parameters

C0070 = x

Proportional gain (V

p

) of speed controller

^ 333

C0071 = x [ms]

Integral−action time (T

n

) of speed controller

Save parameters

C0003 = 1

Save all parameters

Advertising
This manual is related to the following products: