Appendix – Lenze ECSCSxxx User Manual

Page 367

Advertising
background image

Appendix

Code table

13

l

367

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0058 Rotor diff

−90.0

Rotor displacement angle (offset
angle)
Input in case of Lenze motor with

l

resolver: −90°

l

hiperface absolute value
encoder: 0°

Code value is adapted by the
rotor position adjustment
function (C0095).
Only relevant for the operation
of synchronous motors.

^ 151

−180.0

{0.1

_}

179.9

C0059 Mot pole no.

Calculated number of motor pole
pairs
Read only

1

{1}

200

C0060 Rotor pos

Current rotor position; value is
derived from position encoder.
Therefore, it is only valid as rotor
position if the position encoder
settings under C0490 are
identical with the settings of the
speed encoder on the motor
shaft under C0495.
Read only

^ 148

0

{1 inc}

2047 Display with reduced resolution:

1 revolution = 2048 increments

C0061 Heatsink

temp

Heatsink temperature
Read only

^ 204

−200

{1

°C}

200

C0062 Interior temp

Interior device temperature
Read only

^ 205

−200

{1

°C}

200

C0063 Mot temp

Motor temperature
Read only

^ 202

0

{1

°C}

200

C0064 Utilization

Device utilisation (I x t) over the
last 180 s
Only display

0

{1 %}

150

l

C0064 > 100 % activates
OC5−TRIP.

l

TRIP−RESET only is possible if
C0064 < 95 %.

C0065 U24 ext

External low−voltage supply
(U

24

)

Read only

0,0

{0.1V}

100,0

C0066 Motor load

Thermal motor load I

2x

t

Only display

^ 210

0

{1 %}

250

C0067 Act trip

Current fault (TRIP)
(in case of FAIL−QSP, warning and
message, "0" is displayed.)
Only display

^ 238

Advertising
This manual is related to the following products: