9 configuring the digital inputs and outputs, 1 setting the polarity, 2 setting the direction of rotation – Lenze ECSCSxxx User Manual

Page 121: Configuring the digital inputs and outputs, Setting the polarity, Setting the direction of rotation, Commissioning

Advertising
background image

Commissioning

Configuring the digital inputs and outputs

Setting the polarity

6

l

121

EDBCSXS064 EN 4.0

6.9

Configuring the digital inputs and outputs

6.9.1

Setting the polarity

The polarity can be set for each digital input and output. This determines whether the
input or output is HIGH active or LOW active.

The following are available:

ƒ

4 digital inputs (X6/DI1 ... DI4)

ƒ

1 digital output (X6/DO1)

ƒ

1 relay output (X25/BD1, BD2)

The GDC contains codes for setting the polarity of digital inputs and outputs in the
parameter menu under Terminal I/O:

ECSXA308

Fig. 6−7

GDC view: Setting of the polarity of digital inputs and outputs

6.9.2

Setting the direction of rotation

Based on the Lenze setting, the direction of rotation of the motor depends on

ƒ

the sign of the speed setpoint.

ƒ

the polarity of the digital inputs X6/DI1 and X6/DI2.

How to set the polarity/direction of rotation via C0114/x:

ƒ

CW rotation
– C0114/1 = HIGH level active (X6/DI1)
– C0114/2 = LOW level active (X6/DI2)

ƒ

CCW rotation
– C0114/1 = LOW level active (X6/DI1)
– C0114/2 = HIGH level active (X6/DI2)

ƒ

Quick stop (QSP)
– C0114/1 = LOW level active (X6/DI1)
– C0114/2 = LOW level active (X6/DI2)
– See also page

^ 144.

Advertising
This manual is related to the following products: