Appendix – Lenze ECSCSxxx User Manual

Page 403

Advertising
background image

Appendix

Code table

13

l

403

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C2376

XCAN1_OUT mask
(AIF interface X1)

1 XCAN1 Mask

FFFF

0000

{hex}

FFFF Mask for process data output

word 1

2 XCAN1 Mask

FFFF

Mask for process data output
word 2

3 XCAN1 Mask

FFFF

Mask for process data output
word 3

4 XCAN1 Mask

FFFF

Mask for process data output
word 4

C2377

XCAN2_OUT mask
(AIF interface X1)

1 XCAN2 Mask

FFFF

0000

{hex}

FFFF Mask for process data output

word 1

2 XCAN2 Mask

FFFF

Mask for process data output
word 2

3 XCAN2 Mask

FFFF

Mask for process data output
word 3

4 XCAN2 Mask

FFFF

Mask for process data output
word 4

C2378

XCAN3_OUT mask
(AIF interface X1)

1 XCAN3 Mask

FFFF

0000

{hex}

FFFF Mask for process data output

word 1

2 XCAN3 Mask

FFFF

Mask for process data output
word 2

3 XCAN3 Mask

FFFF

Mask for process data output
word 3

4 XCAN3 Mask

FFFF

Mask for process data output
word 4

C2382

The XCAN monitoring is
configured if no telegrams have
been received.
(AIF interface X1)

1 XCAN Conf. CE

0

Off

XCAN1_IN

2 XCAN Conf. CE

0

Off

XCAN2_IN

3 XCAN Conf. CE

0

Off

XCAN3_IN

4 XCAN Conf. CE

0

Off

Bus−off

5 XCAN Conf. CE

0

Off

Life Guarding / Heartbeat Event

6 XCAN Conf. CE

0

Off

Response to sync reception

0

Off

1

Controller inhibit (CINH)

2

Quick stop (QSP)

C2450 CANa address

1

Node address for CAN bus
interface X14 (CAN−AUX)

^ 169

^ 460

1

{1}

63 This code is inactive if one of DIP

switches 2 ... 7 and switch 1 are
set to "ON".

Advertising