Function library

Torque (torque control)

Setting of motor control

12

l

357

EDBCSXS064 EN 4.0

Signal limitation

ƒ

If the drive operates with the maximum torque, the speed controller operates
within the limitation.

ƒ

The drive cannot follow the speed setpoint.

ƒ

The output SPEED−MCTRL.MMax is set to TRUE.

ƒ

The output TORQUE−MCTRL.MMax is set to TRUE.

Set the I component

For selecting torque starting values the integral component of the speed controller can be
set externally (e.g. when using the brake control).

ƒ

In case of speed control ("Speed"):
SPEED−MCTRL.ILoad = TRUE (C7411/12):
– The speed controller accepts the value applied at SPEED−MCTRL.ISet (C7431/8) into

its integral component.

– The value at SPEED−MCTRL.ISet (C7431/8) acts as a torque setpoint for the motor

control.

SPEED−MCTRL.ILoad = FALSE (C7411/12):
– The function is switched off.

ƒ

In case of torque control ("Torque"):
TORQUE−MCTRL.ILoad = TRUE (C7511/7):
– The speed controller accepts the value applied at TORQUE−MCTRL.ISet (C7531/8)

into its integral component.

– The value at TORQUE−MCTRL.ISet (C7431/8) acts as a torque setpoint for the motor

control.

TORQUE−MCTRL.ILoad = FALSE (C7511/7):
– The function is switched off.