Function library – Lenze ECSCSxxx User Manual

Page 352

Advertising
background image

Function library

Torque (torque control)
Setpoint processing

12

l

352

EDBCSXS064 EN 4.0

12.28.3.3

Influencing the ramp function generator

ƒ

If the controller is inhibited, the ramp function generator accepts the actual speed
and passes it to the downstream function. This function has priority over all other
functions.

ƒ

If the input TORQUE−NSET.RfgStop = TRUE (C7511/8), the ramp function generator is
stopped. Changes of the input of the ramp function generator have no effect on the
output signal.

ƒ

If the input TORQUE−NSET.Rfg0 = TRUE (C7511/3) the ramp function generator
reaches zero along the deceleration ramp.

ƒ

The threshold in C0241 specifies when the message "Setpoint reached" is output.
On the ramp function generator for the torque setpoint, the following applies: input
signal = output signal

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0241 NSET RFG I = O

1.00

Threshold for message "Setpoint
reached"
On the ramp function generator
for

l

speed setpoint (for "speed
control")

l

torque setpoint (for "torque
control")

input signal = output signal.

^ 329

^ 352

0.00

{0.01 %}

100.00 100 % = n