6 axis module status, Function library, Dctrl axis module status – Lenze ECSCSxxx User Manual

Page 299: The status is analog coded in the output 36, The status word can be displayed via c0150

Advertising
background image

Function library

DCTRL

Axis module status

12

l

299

EDBCSXS064 EN 4.0

12.17.6

Axis module status

Via "DCTRL−Stat" a status word is output, consisting of signals generated by the DCTRL
function block and signals of freely configurable function block inputs.

ƒ

The status is analog coded in the output 36.

ƒ

The status word can be displayed via C0150.

STAT

C6310/10

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

C0150

C6310/5

C6310/9

C6310/11

36

C6311/5

C6311/6

C6311/7

C6311/8

C6311/9

C6311/10

C6311/11

DCTRL

Warn

Mess

NActEq0

Stat1

Stat2

Stat4

Stat8

Imp

CInh

DCTRL-Stat

DCTRL-StatB0

DCTRL-StatB2

DCTRL-StatB3

DCTRL-StatB4

DCTRL-StatB5

DCTRL-StatB14

DCTRL-StatB15

ECSXA266

Fig. 12−18

DCTRL function block: Output of the status word DCTRL−Stat

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0150 Status word

0

Device status word for
networking via automation
interface (AIF)
Read only

^ 299

0

{1}

65535 Controller evaluates information

as 16 bits (binary−coded)

Bit 0

Not assigned

Bit 1

Pulse inhibit (IMP)

Bit2

Not assigned

Bit3

Not assigned

Bit4

Not assigned

Bit5

Not assigned

Bit 6

n = 0

Bit 7

Controller inhibit (CINH)

Bit 8

Device status bit 1

Bit 9

Device status bit 2

Bit10

Device status bit 3

Bit11

Device status bit 4

Bit12

Warning

Bit13

Message

Bit14

Not assigned

Bit15

Not assigned

Advertising