Electrical installation – Lenze ECSCSxxx User Manual

Page 74

Advertising
background image

Electrical installation

Control terminals
Safe torque off

5

l

74

EDBCSXS064 EN 4.0

5.3.3.4

Technical data

Terminal assignment

Plug connector X6

Terminal Function

Level

Electrical data

X6/S24

Low−voltage supply

18 ... 30 V DC
0.7 A

X6/SO

"Safe torque off" feedback
output

LOW

During operation

24 V DC
0.7 A (max. 1.4 A)
Short−circuit−proof

HIGH

"Safe torque off" active

X6/SI1

Input 1 (controller
enable/inhibit)

LOW

Controller inhibited

LOW level:
−3 ... +5 V
−3 ... +1.5 mA
HIGH level:
+15 ... +30 V
+2 ... +15 mA
Input current at 24 V DC:
8 mA per input

HIGH

Controller enabled

X6/SI2

Input 2 (pulse enable/inhibit)

LOW

Pulses for power section are
inhibited

HIGH

Pulses for power section are
enabled

Cable cross−sections and screw−tightening torques

Cable type

Wire end ferrule

Cable cross−section

Starting torque

Stripping length

Flexible

With insulated wire

end ferrule

0.25 ... 1.5 mm

2

(AWG 22 ... 16)

0.22 ... 0.25 Nm

(1.95 ... 2.2 lb−in)

5 mm for screw
connections
9 mm for spring
connections

Without wire end

ferrule

Not permitted when the "Safe torque off" function is used

Advertising
This manual is related to the following products: