Commissioning – Lenze ECSCSxxx User Manual

Page 119

Advertising
background image

Commissioning

Setting of the feedback system for position and speed control

Absolute value encoder as position encoder and resolver as speed encoder

6

l

119

EDBCSXS064 EN 4.0

Codes for optimising the operation and display

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0058 Rotor diff

−90.0

Rotor displacement angle (offset
angle)
Input in case of Lenze motor with

l

resolver: −90°

l

hiperface absolute value
encoder: 0°

Code value is adapted by the
rotor position adjustment
function (C0095).
Only relevant for the operation
of synchronous motors.

^ 151

−180.0

{0.1

_}

179.9

C0060 Rotor pos

Current rotor position; value is
derived from position encoder.
Therefore, it is only valid as rotor
position if the position encoder
settings under C0490 are
identical with the settings of the
speed encoder on the motor
shaft under C0495.
Read only

^ 148

0

{1 inc}

2047 Display with reduced resolution:

1 revolution = 2048 increments

[C0080] Res pole no.

1

Number of pole pairs of resolver

1

{1}

10

C0414 DIS: ResQual.

Resolver modulation
Quality of the resolver excitation
amplitude set under C0416
(recommendation: 0.5 ... 1.2;
ideal 1.0)

^ 104

0.00

{0.01}

1,60

[C0416] Resolver adj.

5

Resolver excitation amplitude

^ 104

0

100 %

1

80 %

2

68 %

3

58 %

4

50 %

5

45 %

6

40 %

7

37 %

[C0417] Resolver cor.

0

Resolver adjustment

^ 160

0

Ready

1

Start adjustment

2

Loading default values

Advertising
This manual is related to the following products: