Function library

DFOUT (master frequency output)

12

l

304

EDBCSXS064 EN 4.0

12.19

DFOUT (master frequency output)

Function

This function block converts internal speed signals into frequency signals. Transmission is
effected with high precision (without offset and gain errors) with residual value
treatment.

ƒ

The master frequency output X8 can be configured as a master frequency input via
C0491.

ƒ

The type of the master frequency output signals can be set via C0540:
– Output of an analog signal "DFOut−ln_v"
– Output of a speed signal
– Encoder simulation of the resolver with zero track

ƒ

2 to 3 slaves connected to the master:
Use the EMF2132IB digital frequency distributor to wire the ECS axis modules with
master digital frequency cable EYD0017AxxxxW01W01 and slave digital frequency
cable EYD0017AxxxxW01S01.

DFOUT

X8

C0540

0
1
2

CTRL

C0549

C0545
C0030

C0540

0
1
2

n

max

15000 rpm

0

0

1

1

X7

C0491

910

C6431

C6431

C0547

DFOut-Out

DFOut-In_v

ECSXA232

Fig. 12−20

DFOUT function block

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0030 DFOUT const

3

Constant for the digital
frequency signal DFOUT_nOut_v
on X8 in increments per
revolution

^ 304

^ 106

^ 113

0

256 incr./rev

1

512 incr./rev

2

1024 incr./rev

3

2048 incr./rev

4

4096 incr./rev

5

8192 incr./rev

6

16384 incr./rev

[C0491] X8 in/out

0

Function of X8

^ 301

^ 304

^ 106

^ 113

0

X8 is input

1

X8 is output