5 mains fuses, Mains fuses, Appendix – Lenze ECSCSxxx User Manual

Page 466

Advertising
background image

Appendix

Overview of accessories

13

l

466

EDBCSXS064 EN 4.0

13.5.5

Mains fuses

ƒ

Mains fuses are not included in the Lenze delivery program. Use standard fuses.

ƒ

When using ECSxE power supply modules which are fused on the supply side the
DC−bus supply need not be fused.

ƒ

When ECS axis modules are supplied by devices of the 82xx and 93xx series with a
continuous DC current > 40 A, install the following fuses between the supplying
device and the ECS devices:

Fuse

Support

Value [A]

Lenze type

Lenze type

50

EFSGR0500ANIN

EFH20007

ƒ

Observe the national and regional regulations (VDE, UL, EVU, ...).

J

Warnings!

ƒ

Use UL−approved cables, fuses and fuse holders only.

ƒ

UL fuse:
– Voltage 500 ... 600 V
– Tripping characteristic "H", "K5" or "CC"