Commissioning – Lenze ECSCSxxx User Manual

Page 112

Advertising
background image

Commissioning

Setting of the feedback system for position and speed control
TTL/SinCos encoder as position encoder and resolver as speed encoder

6

l

112

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C0420] Encoder const.

512

Number of increments of the
encoder

^ 301

^ 106

^ 113

1

{1 inc/rev}

8192 Sets C0419 = 0 ("common") if the

value is altered.

[C0421] Encoder volt

0

Encoder voltage

^ 301

^ 106

^ 113

0

5.0 V

Sets C0419 = 0 ("common") if the
value is altered.

1

5.6 V

2

6.3 V

3

6.9 V

4

7.5 V

5

8.1 V

[C0427] Enc. signal

0

Function of the master frequency
input signals on X8 (DFIN)

^ 301

^ 106

^ 113

0

2−phase

1

A: speed
B: direction

2

A or B: speed or direction

[C0491] X8 in/out

0

Function of X8

^ 301

^ 304

^ 106

^ 113

0

X8 is input

1

X8 is output

Advertising