10 selecting the operating mode/control structure, Commissioning, Stop – Lenze ECSCSxxx User Manual

Page 126

Advertising
background image

Commissioning

Selecting the operating mode/control structure

6

l

126

EDBCSXS064 EN 4.0

6.10

Selecting the operating mode/control structure

For frequent applications, the controller−internal signal processing is saved in basic
configurations hich can be selected via C3005:

ƒ

Speed control:

Code

Value

Interfaces

Application
examples

Functional
description

C3005

1000

Activation/setpoint via analog input

^ 127

^ 318

1003

Control / setpoint via AIF

^ 130

1005

Control / setpoint via MotionBus (CAN)

^ 132

ƒ

Torque control:

Code

Value

Interfaces

Application
examples

Functional
description

C3005

4000

Activation/setpoint via analog input

^ 134

^ 343

4003

Control / setpoint via AIF

^ 137

4005

Control / setpoint via MotionBus (CAN)

^ 139

(

Stop!

When the internal control structure is changed, another terminal assignment
may result!

In the GDC the code C3005 can be found in the parameter menu under

ƒ

Short setup

W Speed (for speed control).

ƒ

Short setup

W Torque (for torque control).

ECSXA305

Fig. 6−8

GDC view: short setup of the speed control ("Speed")