Commissioning

Configuring the digital inputs and outputs

Change of the terminal assignment

6

l

123

EDBCSXS064 EN 4.0

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C3005 ControlMode

0

Selection of operating modes

^ 126

0

Common

Display with changed standard
application

100

None

Reset of all signal connections

1000

SpeedTerm

Speed−controlled, setpoint via
analog input

^ 318

1003

SpeedAIF

Speed−controlled, setpoint via
AIF

1005

SpeedCAN

Speed−controlled, setpoint via
MotionBus (CAN)

4000

TorqueTerm

Torque−controlled, setpoint via
analog input

^ 343

4003

TorqueAIF

Torque−controlled, setpoint via
AIF

4005

TorqueCAN

Torque−controlled, setpoint via
MotionBus (CAN)

[C6371]

Selection of the digital output
signals for the digital output and
the brake relay

^ 308

1 DigoutIn−dig

1000

0 (FALSE, not assigned)

Source for the output signal at
the digital output X6/DO1
(DigOut−Out1)

2 DigoutIn−dig

1000

0 (FALSE, not assigned)

Source for the control of the
brake relay (DigOut relay)

For possible signals see "selection list − digital
signals"